| Water by crackle test | |
![]() |
|
| OELCHECK Test equipment: |
|
| Sample quantity needed: |
About 0,4 ml |
| Unit: | 4 categories from no to high water content |
| Operating time: | About 5 minutes |
| Analysis of: | All kinds of oils |
| Test result: | Water content |
| Brief description: | |
| Statement: | The crackle test is used for all oil. It is possible to estimate the presence of water in a quick, easy and cost-effective way. The crackle test is used as a “screening” test in addition to IR spectroscopy (water content in %) and Karl Fischer method (water content in ppm). Mostly an oil change is necessary if the crackle test shows a high water content. |