| Visual Evaluation | |
![]() |
|
| OELCHECK Test equipment: |
|
| Sample quantity needed: |
Complete sample container |
| Unit: | Particle > 25 µm |
| Operating time: | About 1 min |
| Analysis of: | All kinds of oils |
| Test result: | Information about contamination, cords and cloudiness |
| Brief description: | Afterwards the sample bottle is turned around and the cap will be opened quickly. Contamination can be easily identified on the white inner surface of the cap. The contamination will be investigated with the help of the illuminated magnifying glass. Estimation about the type and amount of contamination takes place. After investigation a picture is done from the inside of the cap and from the sample bottle. The picture supports the evaluation of the oil sample and is part of the lab report. |
| Statement: | A visual control of the sample with the help of an illuminated magnifying glass, which allows a brief estimation about contamination, cords and cloudiness. |
| Last modified: September 2010, © OELCHECK GmbH | Disclaimer Imprint |